TABLE 25-44: ADC CONVERSION (12-BIT MODE) TIMING REQUIREMENTS
AC CHARACTERISTICS
Standard Operating Conditions: 3.0V to 3.6V
(unless otherwise stated)
Operating temperature -40°C ≤TA ≤+85°C for Industrial
-40°C ≤TA ≤+125°C for Extended
Param
No.
Symbol
Characteristic
Min. Typ(1) Max. Units
Conditions
Clock Parameters
AD50a TAD
ADC Clock Period
117.6 —
—
ns
—
AD51a tRC
ADC Internal RC Oscillator
—
250
—
ns
—
Period
Conversion Rate
AD55a tCONV Conversion Time
— 14 TAD
ns
—
AD56a FCNV
Throughput Rate
—
— 500 ksps
—
AD57a tSAMP Sample Time
3 TAD
—
—
—
—
Timing Parameters
AD60a tPCS
Conversion Start from Sample
Trigger(2)
2.0 TAD
— 3.0 TAD — Auto-Convert Trigger
(SSRC<2:0> = 111) not
selected
AD61a tPSS
Sample Start from Setting
2.0 TAD — 3.0 TAD —
—
Sample (SAMP) bit(2)
AD62a tCSS
Conversion Completion to
— 0.5 TAD —
—
—
Sample Start (ASAM = 1)(2)
AD63a tDPU
Time to Stabilize Analog Stage
—
—
20
μs
—
from ADC Off to ADC On(2,3)
Note 1: These parameters are characterized but not tested in manufacturing.
2: Because the sample caps will eventually lose charge, clock rates below 10 kHz can affect linearity
performance, especially at elevated temperatures.
3: tDPU is the time required for the ADC module to stabilize when it is turned on (AD1CON1<ADON> = 1).