dsPIC30F2011/2012/3012/3013
TABLE 20-14: EXTERNAL CLOCK TIMING REQUIREMENTS
AC CHARACTERISTICS
Standard Operating Conditions: 2.5V to 5.5V
(unless otherwise stated)
Operating temperature -40°C ≤ TA ≤ +85°C for Industrial
-40°C ≤ TA ≤ +125°C for Extended
Param
No.
Symbol
Characteristic
Min
Typ(1) Max Units
Conditions
OS10 FOSC External CLKN Frequency(2)
DC
(External clocks allowed only
4
in EC mode)
4
4
—
40
MHz EC
—
10
MHz EC with 4x PLL
—
10
MHz EC with 8x PLL
—
7.5 MHz EC with 16x PLL
Oscillator Frequency(2)
DC
—
4
MHz RC
0.4
—
4
MHz XTL
4
—
10
MHz XT
4
—
10
MHz XT with 4x PLL
4
—
10
MHz XT with 8x PLL
4
—
7.5 MHz XT with 16x PLL
10
—
25
MHz HS
10
—
20
MHz HS/2 with 4x PLL
10
—
20
MHz HS/2 with 8x PLL
10
—
15
MHz HS/2 with 16x PLL
12
—
25
MHz HS/3 with 4x PLL
12
—
25
MHz HS/3 with 8x PLL
12
—
22.5 MHz HS/3 with 16x PLL
31
—
33
kHz LP
—
7.37
—
MHz FRC internal
—
7.37
—
MHz FRC internal w/4x PLL
—
7.37
—
MHz FRC internal w/8x PLL
—
7.37
—
MHz FRC internal w/16x PLL
—
512
—
kHz LPRC internal
OS20 TOSC TOSC = 1/FOSC
—
OS25 TCY
Instruction Cycle Time(2)(3)
33
—
—
— See parameter OS10
for FOSC value
—
DC
ns See Table 20-17
OS30 TosL, External Clock(2) in (OSC1)
.45 x
—
—
ns EC
TosH High or Low Time
TOSC
OS31 TosR, External Clock(2) in (OSC1)
—
TosF Rise or Fall Time
—
20
ns EC
OS40 TckR CLKO Rise Time(2)(4)
—
—
—
ns See parameter DO31
OS41 TckF
CLKO Fall Time(2)(4)
—
—
—
ns See parameter DO32
Note 1: Data in “Typ” column is at 5V, 25°C unless otherwise stated. Parameters are for design guidance only and
are not tested.
2: These parameters are characterized but not tested in manufacturing.
3: Instruction cycle period (TCY) equals four times the input oscillator time-base period. All specified values
are based on characterization data for that particular oscillator type under standard operating conditions
with the device executing code. Exceeding these specified limits may result in an unstable oscillator
operation and/or higher than expected current consumption. All devices are tested to operate at “min.”
values with an external clock applied to the OSC1/CLKI pin. When an external clock input is used, the
“Max.” cycle time limit is “DC” (no clock) for all devices.
4: Measurements are taken in EC or ERC modes. The CLKO signal is measured on the OSC2 pin. CLKO is
low for the Q1-Q2 period (1/2 TCY) and high for the Q3-Q4 period (1/2 TCY).
DS70139F-page 158
© 2008 Microchip Technology Inc.