M48T35AY, M48T35AV
DC AND AC PARAMETERS
This section summarizes the operating and mea-
surement conditions, as well as the DC and AC
characteristics of the device. The parameters in
the following DC and AC Characteristic tables are
derived from tests performed under the Measure-
ment Conditions listed in the relevant tables. De-
signers should check that the operating conditions
in their projects match the measurement condi-
tions when using the quoted parameters.
Table 7. Operating and AC Measurement Conditions
Parameter
M48T35AY
M48T35AV
Unit
Supply Voltage (VCC)
4.5 to 5.5
3.0 to 3.6
V
Grade 1
0 to 70
0 to 70
°C
Ambient Operating Temperature (TA)
Grade 6
–40 to 85
–40 to 85
Load Capacitance (CL)
100
50
pF
Input Rise and Fall Times
≤5
≤5
ns
Input Pulse Voltages
0 to 3
0 to 3
V
Input and Output Timing Ref. Voltages
1.5
Note: Output Hi-Z is defined as the point where data is no longer driven.
1.5
V
Figure 14. AC Measurement Load Circuit
DEVICE
UNDER
TEST
645Ω
CL = 100pF
(or 5pF)
1.75V
CL includes JIG capacitance
Note: 50pF for M48T35AV.
AI02586
Table 8. Capacitance
Symbol
Parameter(1,2)
Min
Max
CIN
Input Capacitance
10
COUT(3)
Output Capacitance
10
Note: 1. Effective capacitance measured with power supply at 5V; sampled only, not 100% tested.
2. At 25°C, f = 1MHz.
3. Outputs deselected.
Unit
pF
pF
16/25