ST7LITEU05 ST7LITEU09
13.3.2 Operating Conditions with Low Voltage Detector (LVD)
TA = -40 to 125°C, unless otherwise specified
Symbol
Parameter
Conditions
Min Typ Max Unit
VIT+(LVD)
Reset release threshold
(VDD rise)
VIT-(LVD)
Reset generation threshold
(VDD fall)
High Threshold
Med. Threshold
Low Threshold
High Threshold
Med. Threshold
Low Threshold
3.9
4.2
4.5
3.2
3.5
3.8
2.5
2.7
3.0
V
3.7
4.0
4.3
3.0
3.3
3.6
2.4
2.6
2.9
Vhys
VtPOR
IDD(LVD) 1)
LVD voltage threshold hysteresis
VDD rise time rate 2) 3)
LVD/AVD current consumption
VIT+(LVD)-VIT-(LVD)
VDD = 5V
150
20
220
mV
µs/V
µA
Notes:
1. Not tested in production.
2. Not tested in production. The VDD rise time rate condition is needed to ensure a correct device power-on and LVD reset
release. When the VDD slope is outside these values, the LVD may not release properly the reset of the MCU.
3. Use of LVD with capacitive power supply: with this type of power supply, if power cuts occur in the application, it is
recommended to pull VDD down to 0V to ensure optimum restart conditions. Refer to circuit example in Figure 66 on page
97.
13.3.3 Auxiliary Voltage Detector (AVD) Thresholds
TA = -40 to 125°C, unless otherwise specified
Symbol
Parameter
Conditions
VIT+(AVD)
1=>0 AVDF flag toggle threshold
(VDD rise)
High Threshold
Med. Threshold
Low Threshold
VIT-(AVD)
0=>1 AVDF flag toggle threshold
(VDD fall)
High Threshold
Med. Threshold
Low Threshold
Vhys
AVD voltage threshold hysteresis VIT+(AVD)-VIT-(AVD)
Note:
1. Not tested in production, guaranteed by characterization.
Note: Refer to section 8.4.2.1 on page 35
Min 1)
4.0
3.4
2.6
3.9
3.3
2.5
Typ 1)
4.4
3.7
2.9
4.3
3.6
2.8
150
Max 1)
4.8
4.1
3.2
4.7
4.0
3.1
Unit
V
mV
77/115