DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MCP3421DM-WS View Datasheet(PDF) - Microchip Technology

Part Name
Description
Manufacturer
MCP3421DM-WS
Microchip
Microchip Technology 
MCP3421DM-WS Datasheet PDF : 26 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
Product Overview
TABLE 1-1: JUMPERS POSITIONS VS. FUNCTION
Symbol
Jumpers Positions
Function
xPGA(1) J4 and J5 connected to J19
J10 and J13 are ON
J8, J9, J11 and J12 are disconnected (Figure 1-3a)
xGLo(1) J4 and J5 connected to GND
J9, J11 and J12 are ON
J8, J10 and J13 are disconnected (Figure 1-3b)
xGHi(1) J4 and J5 connected to GND
J8, J11 and J12 are ON
J9, J10 and J13 are disconnected (Figure 1-3c)
Note 1: x indicates the selected averaging factor (1 or 4).
This combination evaluates the ADC perfor-
mance. The on-board op amp is bypassed.
This combination evaluates the influence of the
extra gain added by the MCP6V07 device.
This combination evaluates the influence of the
extra gain added by the MCP6V07 device, but
with higher extra gain.
FIGURE 1-3:
Gain Selection Options on MCP3421 Weight Scale Demo Board.
1.3 LOAD CELL
The MCP3421 device with a maximum PGA gain setting (8x) can detect an input signal
level as low as 2 µV. Therefore, it can detect the input with an accuracy of 1g. When
measuring such a low input signal level, to control the noise level at the input pins is
very important. Therefore, using low-noise op amp at the signal conditioning circuit is
necessary. In this demo board, MCP6V07 auto-zeroed op amp is used. This op amp
has the offset voltage less than ±2 µV, and drifts less than ±50 nV/C.
Additional improvement in signal-to-noise ratio can be achieved by doing more averag-
ing in digital domain. The user can tell the difference by selecting the data average
options 1 or 4. The results are shown in the PC GUI.
Note:
This demo board uses a low-cost load cell for demonstration purposes. The
load cell can measure up to 2 Kg with 1 mV/V sensitivity. The load cell
output is connected to the demo board PCB through J18 and J19
connectors. The user can also connect their own load cell instead.
2010 Microchip Technology Inc.