Electrical characteristics
STM32F301x6 STM32F301x8
Symbol Parameter
Table 67. ADC accuracy (1)(2)(3) (continued)
Conditions
Min(4)
Max
(4)
Unit
Fast channel 5.1 Ms 64
Single ended
SNR(5)
Signal-to-
noise ratio
Slow channel 4.8 Ms 64
Fast channel 5.1 Ms 67
ADC clock freq. ≤ 72 MHz, Differential Slow channel 4.8 Ms
67
Sampling freq ≤ 5 Msps,
Total
THD(5) harmonic
2 V ≤ VDDA ≤ 3.6 V
Fast channel 5.1 Ms
Single ended
-
Slow channel 4.8 Ms
-
distortion
Fast channel 5.1 Ms
-
Differential
Slow channel 4.8 Ms
-
-
-
-
-
dB
-75
-75
-79
-78
1. ADC DC accuracy values are measured after internal calibration.
2. ADC accuracy vs. negative Injection Current: Injecting negative current on any analog input pins should be avoided as this
significantly reduces the accuracy of the conversion being performed on another analog input. It is recommended to add a
Schottky diode (pin to ground) to analog pins which may potentially inject negative current.
Any positive
accuracy.
injection
current
within
the
limits
specified
for
IINJ(PIN)
and
ΣIINJ(PIN)
in
Section
6.3.14
does
not
affect
the
ADC
3. Better performance may be achieved in restricted VDDA, frequency and temperature ranges.
4. Guaranteed by characterization results.
5. Value measured with a –0.5dB Full Scale 50kHz sine wave input signal.
Symbol
Parameter
Table 68. ADC accuracy(1)(2)
Test conditions
Typ
Max(3) Unit
ET Total unadjusted error
Fast channel
Slow channel
Fast channel
EO Offset error
Slow channel
ADC Freq ≤ 72 MHz
EG Gain error
Sampling Freq ≤ 1MSPS
Fast channel
2.4 V ≤ VDDA = VREF+ ≤ 3.6 V Slow channel
Single-ended mode
Fast channel
ED Differential linearity error
Slow channel
EL Integral linearity error
Fast channel
Slow channel
±2.5
±5
±3.5
±5
±1
±2.5
±1.5
±2.5
±2
±3
LSB
±3
±4
±0.7
±2
±0.7
±2
±1
±3
±1.2
±3
1. ADC DC accuracy values are measured after internal calibration.
2. ADC accuracy vs. negative Injection Current: Injecting negative current on any analog input pins should be avoided as this
significantly reduces the accuracy of the conversion being performed on another analog input. It is recommended to add a
Schottky diode (pin to ground) to analog pins which may potentially inject negative current. Any positive injection current
within the limits specified for IINJ(PIN) and ∑IINJ(PIN) in Section 6.3.14: I/O port characteristics does not affect the ADC
accuracy.
3. Guaranteed by characterization results.
106/135
DocID025146 Rev 6

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]