Electrical specifications
TDA75610DLVPD
Table 5. Electrical characteristics (continued)
Symbol
Parameter
Test condition
Min. Typ. Max. Unit
ASB Standby attenuation
-
AM Mute attenuation
-
Turn on diagnostics 1 (Power amplifier mode)
90
110
-
dB
80
100
-
dB
Pgnd
Pvs
Pnop
Lsc
Lop
Lnop
Short to GND det. (below this
limit, the Output is considered in
short circuit to GND)
Short to Vs det. (above this limit,
the output is considered in short
circuit to Vs)
Normal operation thresholds.
(Within these limits, the output is
considered without faults).
Power amplifier in standby
Shorted load det.
Open load det.
Normal load det.
-
-
1.2
V
Vs -1.2 -
-
V
1.8
- Vs -1.8 V
-
-
0.5
Ω
85
-
-
Ω
1.5
-
45
Ω
Turn on diagnostics 2 (Line driver mode)
Pgnd
Pvs
Pnop
Lsc
Lop
Lnop
Short to GND det. (below this
limit, the output is considered in
short circuit to GND)
Power amplifier in standby
Short to Vs det. (above this limit,
the output is considered in short -
circuit to Vs)
Normal operation thresholds.
(Within these limits, the output is -
considered without faults).
Shorted load det.
-
Open load det.
-
Normal load det.
-
-
-
1.2
V
Vs -1.2 -
-
V
1.8
- Vs -1.8 V
-
-
1.5
Ω
330
-
-
Ω
7
-
180
Ω
Permanent diagnostics 2 (Power amplifier mode or line driver mode)
Pgnd
Short to GND det. (below this
limit, the Output is considered in
short circuit to GND)
-
-
1.2
V
Short to Vs det. (above this limit, Power amplifier in mute or play,
Pvs the output is considered in short one or more short circuits
Vs -1.2 -
circuit to Vs)
protection activated
-
V
Pnop
Normal operation thresholds.
(Within these limits, the output is
considered without faults).
1.8
- Vs -1.8 V
LSC Shorted load det.
Power amplifier mode
Line driver mode
-
-
0.5
Ω
-
-
1.5
Ω
12/37