M48T59, M48T59Y, M48T59V
Clock operations
Table 5. Register map
Data
Address
D7 D6 D5 D4 D3 D2 D1 D0
Function/range
BCD format
1FFFh
10 Years
Year
Year
00-99
1FFEh
0
0
0 10 M
Month
Month
01-12
1FFDh
0
0
10 date
Date
Date
01-31
1FFCh
0 FT CEB CB 0
Day
Century/day 00-01/01-07
1FFBh
0
0 10 hours
Hours
Hours
00-23
1FFAh
0
10 minutes
Minutes
Minutes
00-59
1FF9h ST
10 seconds
Seconds
Seconds
00-59
1FF8h
WRS
Calibration
Control
1FF7h
WDS
BMB
4
BMB
3
BMB
2
BMB
1
BMB
0
RB1
RB0
Watchdog
1FF6h
1FF5h
t(s) 1FF4h
c 1FF3h
u 1FF2h
rod 1FF1h
P 1FF0h
AFE Y ABE Y
RPT4 Y Al. 10 date
RPT3 Y Al. 10 hours
RPT2 Alarm 10 minutes
RPT1 Alarm 10 seconds
Y
Y
YY
WDF AF Z BL
Y Y YY
Alarm date
Alarm hours
Alarm minutes
Alarm seconds
Y Y YY
Z Z ZZ
te Keys:
le S = Sign bit
so FT = Frequency test bit
b R = Read bit
- O W = Write bit
t(s) ST = Stop bit
0 = Must be set to '0'
uc Y = '1' or '0'
rod Z = '0' and are read only
AF = Alarm flag (read only)
te P BL = Battery low (read only)
le WDS = Watchdog steering bit
o BMB0-BMB4 = Watchdog multiplier bits
bs RB0-RB1 = Watchdog resolution bits
O AFE = Alarm flag enable
Interrupts
Alarm date
Alarm hours
Alarm minutes
Alarm seconds
Unused
Flags
01-31
00-23
00-59
00-59
ABE = Alarm in battery back-up mode enable
RPT1-RPT4 = Alarm repeat mode bits
WDF = Watchdog flag (read only)
CEB = Century enable bit
CB = Century bit
13/32