ST6200C/ST6201C/ST6203C
CLOCK AND TIMING CHARACTERISTICS (Cont’d)
11.5.4 RC Oscillator
The ST6 internal clock can be supplied with an external RC oscillator. Depending on the RNET value, the
accuracy of the frequency is about 20%, so it may not be suitable for some applications.
Symbol
Parameter
Conditions
Min Typ Max Unit
fOSC
RC oscillator frequency 1)
RNET
RC Oscillator external resistor 2)
RNET=22 kΩ
7.2
RNET=47 kΩ
5.1
RNET=100 kΩ
3.2
RNET=220 kΩ
1.8
RNET=470 kΩ
0.9
RNET=22 kΩ
3.7
RNET=47 kΩ
2.8
RNET=100 kΩ
1.8
RNET=220 kΩ
1
RNET=470 kΩ
0.5
see Figure 46 & Figure 47 22
8.6
5.7
3.4
1.9
0.95
4.3
3
1.9
1.1
0.55
10
6.5
3.8
2
1.1
MHz
4.9
3.3
2
1.2
0.6
870 kΩ
Notes:
1. Data based on characterization results, not tested in production. These measurements were done with the OSCin pin
unconnected (only soldered on the PCB).
2. RNET must have a positive temperature coefficient (ppm/°C), carbon resistors should therefore not be used.
Figure 45. Typical Application with RC Oscillator
EXTERNAL RC
OSCOUT
RNET
OSCIN
NC
fOSC
VDD
VDD
VDD
MIRROR
CURRENT
70/100
1
CEX~9pF DISCHARGE
ST62XX