Maximum rating
M24256-BW M24256-BR M24256-BF M24256-DR M24256-DF
7
Maximum rating
Stressing the device outside the ratings listed in Table 5 may cause permanent damage to
the device. These are stress ratings only, and operation of the device at these, or any other
conditions outside those indicated in the operating sections of this specification, is not
implied. Exposure to absolute maximum rating conditions for extended periods may affect
device reliability.
Table 5. Absolute maximum ratings
Symbol
Parameter
Min.
Max. Unit
Ambient operating temperature
–40
130
°C
TSTG
TLEAD
IOL
VIO
VCC
VESD
Storage temperature
Lead temperature during soldering
DC output current (SDA = 0)
Input or output range
Supply voltage
Electrostatic pulse (Human Body model)(2)
–65
150
°C
see note (1)
°C
-
5
mA
–0.50
6.5
V
–0.50
6.5
V
-
4000(3)
V
1. Compliant with JEDEC Std J-STD-020D (for small body, Sn-Pb or Pb assembly), the ST ECOPACK®
7191395 specification, and the European directive on Restrictions on Hazardous Substances (RoHS)
2002/95/EU.
2. Positive and negative pulses applied on different combinations of pin connections, according to AEC-
Q100-002 (compliant with JEDEC Std JESD22-A114, C1=100 pF, R1=1500 Ω).
3. 3000 V for previous devices (process letters KA).
22/40