M24256-BW M24256-BR M24256-BF M24256-DR M24256-DF
8
DC and AC parameters
DC and AC parameters
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device.
Table 6. Operating conditions (voltage range W)
Symbol
Parameter
Min.
VCC Supply voltage
2.5
TA
Ambient operating temperature
–40
fC
Operating clock frequency
-
Max.
5.5
85
1
Unit
V
°C
MHz
Table 7. Operating conditions (voltage range R)
Symbol
Parameter
Min.
VCC Supply voltage
1.8
TA
Ambient operating temperature
–40
fC
Operating clock frequency
-
Max.
5.5
85
1
Unit
V
°C
MHz
Table 8. Operating conditions (voltage range F)
Symbol
Parameter
Min.
VCC Supply voltage
1.7
TA
Ambient operating temperature
–40
fC
Operating clock frequency
-
Max.
5.5
85
1
Unit
V
°C
MHz
Table 9. AC measurement conditions
Symbol
Parameter
Cbus
Load capacitance
SCL input rise/fall time, SDA input fall time
Input levels
Input and output timing reference levels
Min.
Max.
100
-
50
0.2 VCC to 0.8 VCC
0.3 VCC to 0.7 VCC
Figure 11. AC measurement I/O waveform
)NPUT VOLTAGE LEVELS
6##
6##
)NPUT AND OUTPUT
4IMING REFERENCE LEVELS
6##
6##
Unit
pF
ns
V
V
-36
Doc ID 6757 Rev 30