MB89670/A Series
2. Recommended Operating Conditions
Parameter
Power supply voltage
A/D converter reference input
voltage
Operating temperature
Symbol
VCC
AVR
TA
Value
Min. Max.
2.2* 6.0
2.7* 6.0
1.5 6.0
0.0 AVCC
–40 +85
Unit
(AVSS = VSS = 0.0 V)
Remarks
V
Normal operation assurance range
MB89673/677A
V
Normal operation assurance range
MB89PV670A/P677A
V Retains the RAM state in stop mode
V
°C
* : These values vary with the operating frequency, and analog assurance range. See Figure 1 and “5. A/D Converter
Electrical Characteristics.”
6
5
Operation assurance range
4
A/D converter accuracy assured in the
VCC = AVCC = 3.5 V to 6.0 V range.
3
2
1
1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0
Clock operating frequency (MHz)
4.0 2.0
0.8
0.4
Minimum execution time (µs)
Note: The shaded area is assured only for the MB89673/677A.
Figure 1 Operating Voltage vs. Clock Operating Frequency
Figure 1 indicates the operating frequency of the external oscillator at an minimum execution time of 4/FC.
Since the operating voltage range is dependent on the minimum execution time, see minimum execution time
if the operating speed is switched using a gear.
29