MAT01
TYPICAL APPLICATIONS
R1
1.5kΩ
1mA
Q1
VREF
Q2
VREF ≈ 7.0V
TCVREF ≈ 100ppm/°C
RO ≈ 40Ω
NOTES
1. R1 MAY BE ADJUSTED TO MINIMIZE TCVREF.
INCREASING R1 CAUSES A POSITIVE CHANGE IN TCVREF.
2. hFE OF Q1 IS REDUCED BY OPERATION OF BREAKDOWN MODE.
Figure 13. Precision Reference
SENSING PAIR
MAT01H
UP TO
100 FEET
CABLE
+15V
–15V
DIFFERENTIAL
EO = 10mV/K
AMPLIFIER AND
CURRENT SOURCES
°C
K
EO
–55°C = 218K = 2.18V
+25°C = 298K = 2.98V
+125°C = 398K = 3.98V
3-DIGIT DPM
0V TO +10V
FULL SCALE
Figure 14. Basic Digital Thermometer Readout in Degrees Kelvin (K)
SENSING PAIR
MAT01H
UP TO
100FT.
CABLE
+15V
–15V
DIFFERENTIAL
EO = 10mV/K
AMPLIFIER AND
CURRENT SOURCES
2.73V
+
POWER SUPPLY –
HIGH
LOW
2 1/2 DIGIT
DPM BIPOLAR
DIFFERENTIAL
INPUTS
METER DISPLAYS
EO –2.73V
–55°C = –0.55V
+25°C = +0.25V
+125°C = +1.25V
Figure 15. Digital Thermometer with Readout in °C
Data Sheet
Rev. C | Page 10 of 12