STM6600 - STM6601
7
DC and AC characteristics
DC and AC characteristics
This section summarizes the operating measurement conditions and the DC and AC
characteristics of the device. The parameters in the DC and AC characteristics tables that
follow are derived from tests performed under the measurement conditions summarized in
Table 4. Designers should check that the operating conditions in their circuit match the
operating conditions when relying on the quoted parameters.
Table 4. Operating and AC measurement conditions
Parameter
Condition
Unit
VCC supply voltage
Ambient operating temperature (TA)
Input rise and fall times
1.6 to 5.5
V
–40 to 85
°C
≤_5
ns
Table 5.
Symbol
DC and AC characteristics
Parameter
Test condition(1)
VCC Supply voltage
ICC Supply current
VCC = 3.6 V, no load
Standby mode, enable
deasserted, VCC = 3.6 V
VTH+
Power-on lockout voltage
(see Table 10 for detailed
listing)
VHYST
Threshold hysteresis (see
Table 10 for detailed listing)
VTH–
tTH–
Forced power-off voltage
(see Table 10 for detailed
listing)
Undervoltage detection to
INT delay
VCC ≥ 2.0 V
Blanking period (see
tON_BLANK Table 10 for detailed
listing)(3)
RST assertion to EN (EN)
assertion delay during
power-up
VCC = 3.6 V
Min.
1.6
2.40
3.00
3.20
3.29
3.39
Typ.(2)
6
2.50
3.10
3.30
3.40
3.50
200
500
Max. Unit
5.5 V
8 µA
1 µA
2.60
3.20
3.40 V
3.51
3.61
mV
VTH+ – VHYST
V
20
32
44 ms
1.4
2.2
3.0
5.6
8.8
12.0 s
11.2
17.6
24.0
100
ns
Doc ID 15453 Rev 7