Write to Camera
VV5430
10.2 Header Codes
The message can be a configuration word, an exposure, gain or calibration value. The camera’s interpretation of the header code
and the set-up code message are given in the table below. Defaults for each control bit are built in to the camera’s reset cycle,
and may be changed on-the-fly under host control.
Code
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111
Interpretation
Comment
Invalid
Set-up code_1 (9 bits)
Basic funtionality options
Set-up code_2 (9 bits)
Pixel control & Read Data
Coarse exposure value (9 bits)
Set AEC=0 to enable
Fine exposure value (9 bits)
Set AEC=0 to enable
Gain control value (4 bits)
Set AGC=0 to enable
Unused
Unused
Exposure control T1 threshold (9 bit)
Exposure control T2 threshold (9 bit)
Analogue control register (8 bit)
Reserved
Not applicable to normal use
Reserved
Not applicable to normal use
Reserved
Not applicable to normal use
Set-up code_3 (6 bits)
Pixel synchronisation
Test mode select
Not applicable to normal use
Table 14 : Header Codes