ELECTRICAL CHARACTERISTICS (CONTINUED)
SWITCHING ON
Symbol
Parameter
td(on)
tr
Turn-on Delay Time
Rise Time
Qg
Total Gate Charge
Qgs
Gate-Source Charge
Qgd
Gate-Drain Charge
Test Conditions
VDD = 500 V, ID = 2.5 A
RG = 4.7Ω VGS = 10 V
(see test circuit, Figure 3)
VDD = 800V, ID = 5 A,
VGS = 10V
SWITCHING OFF
Symbol
Parameter
tr(Voff)
Off-voltage Rise Time
tf
Fall Time
tc
Cross-over Time
Test Conditions
VDD = 800V, ID = 5 A,
RG = 4.7Ω, VGS = 10V
(see test circuit, Figure 5)
SOURCE DRAIN DIODE
Symbol
Parameter
Test Conditions
ISD
Source-drain Current
ISDM (1) Source-drain Current (pulsed)
VSD (2) Forward On Voltage
ISD = 5 A, VGS = 0
trr
Qrr
IRRM
Reverse Recovery Time
Reverse Recovery Charge
Reverse Recovery Current
ISD = 5 A, di/dt = 100A/µs,
VDD = 100V, Tj = 150°C
(see test circuit, Figure 5)
Note: 1. Pulsed: Pulse duration = 300 µs, duty cycle 1.5 %.
2. Pulse width limited by safe operating area.
STP5NB100 - STP5NB100FP
Min. Typ. Max. Unit
24
ns
11
ns
39
51
nC
9.6
nC
19.2
nC
Min.
Typ.
20
22
26
Max.
Unit
ns
ns
ns
Min. Typ. Max. Unit
5
A
20
A
1.6
V
780
ns
5.5
µC
14
A
Safe Operating Area for TO-220
Safe Operating Area for TO-220FP
3/9