ELECTRICAL CHARACTERISTICS (CONTINUED)
SWITCHING ON
Symbol
Parameter
Test Conditions
td(on)
tr
Turn-on Delay Time
Rise Time
VDD = 30V, ID = 7 A
RG = 4.7Ω VGS = 10V
(see test circuit, Figure 3)
Qg
Total Gate Charge
Qgs
Gate-Source Charge
Qgd
Gate-Drain Charge
VDD = 48 V, ID = 14 A,
VGS = 10V
SWITCHING OFF
Symbol
Parameter
td(off)
tf
Turn-off-Delay Time
Fall Time
Test Conditions
VDD = 30 V, ID = 7 A,
RG = 4.7Ω, VGS = 10V
(see test circuit, Figure 3)
STP14NF06
Min. Typ. Max. Unit
12.5
ns
32
ns
11.2
15
nC
3.7
nC
3.2
nC
Min.
Typ.
30
9.5
Max.
Unit
ns
ns
SOURCE DRAIN DIODE
Symbol
Parameter
Test Conditions
ISD
Source-drain Current
ISDM (1) Source-drain Current (pulsed)
VSD (2) Forward On Voltage
ISD = 14 A, VGS = 0
trr
Qrr
IRRM
Reverse Recovery Time
Reverse Recovery Charge
Reverse Recovery Current
ISD = 14 A, di/dt = 100A/µs,
VDD = 30 V, Tj = 150°C
(see test circuit, Figure 5)
Note: 1. Pulsed: Pulse duration = 300 µs, duty cycle 1.5 %.
2. Pulse width limited by safe operating area.
Min. Typ. Max. Unit
14
A
56
A
1.3
V
38
ns
61
nC
3.2
A
Safe Operating Area
Thermal Impedence
3/8