ELECTRICAL CHARACTERISTICS (CONTINUED)
SWITCHING ON
Symbol
Parameter
td(on)
Turn-on Delay Time
tr
Rise Time
Qg
Total Gate Charge
Qgs
Gate-Source Charge
Qgd
Gate-Drain Charge
Test Conditions
VDD = 300 V, ID = 3 A
RG = 4.7Ω VGS = 10 V
(see test circuit, Figure 3)
VDD = 480V, ID = 6 A,
VGS = 10V
SWITCHING OFF
Symbol
Parameter
tr(Voff)
Off-voltage Rise Time
tf
Fall Time
tc
Cross-over Time
Test Conditions
VDD = 480V, ID = 6 A,
RG = 4.7Ω, VGS = 10V
(see test circuit, Figure 5)
SOURCE DRAIN DIODE
Symbol
Parameter
Test Conditions
ISD
Source-drain Current
ISDM (2) Source-drain Current (pulsed)
VSD (1) Forward On Voltage
ISD = 6 A, VGS = 0
trr
Qrr
IRRM
Reverse Recovery Time
Reverse Recovery Charge
Reverse Recovery Current
ISD =6 A, di/dt = 100A/µs
VDD = 100V, Tj = 150°C
(see test circuit, Figure 5)
Note: 1. Pulsed: Pulse duration = 300 µs, duty cycle 1.5 %.
2. Pulse width limited by safe operating area.
STP6LNC60/STP6LNC60FP
Min. Typ. Max. Unit
14.5
ns
15.5
ns
28
39
nC
4.8
nC
17.5
nC
Min.
Typ.
9
7.5
16
Max.
Unit
ns
ns
ns
Min. Typ. Max. Unit
5.8
A
23.2
A
1.6
V
450
ns
2.4
µC
10.6
A
Safe Operating Area for TO-220
Safe Operating Area for TO-220FP
3/9