STGW30NC120HD
Electrical characteristics
Table 6. Switching on/off (inductive load)
Symbol
Parameter
Test conditions
td(on)
tr
(di/dt)on
Turn-on delay time
Current rise time
Turn-on current slope
td(on)
tr
(di/dt)on
Turn-on delay time
Current rise time
Turn-on current slope
tr(Voff)
td(off)
tf
Off voltage rise time
Turn-off delay time
Current fall time
tr(Voff)
td(off)
tf
Off voltage rise time
Turn-off delay time
Current fall time
VCC = 960V, IC = 20A
RG= 10Ω, VGE= 15V,
Tj=25°C (see Figure 17)
VCC = 960V, IC = 20A
RG= 10Ω, VGE= 15V,
Tj= 125°C (see Figure 17)
VCC = 960V, IC = 20A
RG= 10Ω, VGE= 15V,
Tj= 25°C (see Figure 17)
VCC = 960V, IC = 20A
RG= 10Ω, VGE= 15V,
Tj= 125°C (see Figure 17)
Min. Typ. Max. Unit
29
11
1820
ns
ns
A/µs
27
14
1580
ns
ns
A/µs
90
ns
275
ns
312
ns
150
ns
336
ns
592
ns
Table 7. Switching energy (inductive load)
Symbol
Parameter
Test conditions
Min. Typ. Max. Unit
Eon (1)
Eoff (2)
Ets
Turn-on switching losses
Turn-off switching losses
Total switching losses
VCC = 960V, IC = 20A
RG= 10Ω, VGE= 15V,
Tj= 25°C (see Figure 17)
1660
µJ
4438
µJ
6098
µJ
Eon (1)
Eoff (2)
Ets
Turn-on switching losses
Turn-off switching losses
Total switching losses
VCC = 960V, IC = 20A
RG= 10Ω, VGE= 15V,
Tj= 125°C (see Figure 17)
3015
µJ
6900
µJ
9915
µJ
1. Eon is the turn-on losses when a typical diode is used in the test circuit in figure 2. If the IGBT is offered in
a package with a co-pack diode, the co-pack diode is used as external diode. IGBTs & Diode are at the
same temperature (25°C and 125°C)
2. Turn-off losses include also the tail of the collector current
Table 8. Collector-emitter diode
Symbol
Parameter
Test conditions
Vf
Forward on-voltage
If = 20A, Tj = 25°C
If = 20A, Tj = 125°C
trr
Reverse recovery time
If = 20A, VR = 27V,
Qrr
Reverse recovery charge Tj = 125°C, di/dt = 100A/µs
Irrm Reverse recovery current (see Figure 20)
Min.
Typ. Max. Unit
1.9 2.5 V
1.7
V
152
ns
722
nC
9
A
5/13