6.6.4. Error Handling
If a Write User Zone command containing transmission errors is received by the PICC, it is ignored and no response is
sent. The PICC reports errors in the status byte of the response.
Table 26. Status Codes returned in the Write User Zone response
Error/Status Message
No errors
Write Pending – Checksum Required
One Byte Written (Write Lock Mode)
Access Denied (User Zone Not Set)
Access Denied (Security Fuses Invalid)
PARAM Invalid
Address Invalid
Length Invalid
Authentication or Encryption Activation Required
Data Written (Program Only Mode)
Access denied (Write Lock Mode)
Checksum Failure
Password Required
Modify Forbidden
Memory Write Error - Data Mismatch
Memory Access Error
Status Code
$00
$0C
$1B
$99
$99
$A1
$A2
$A3
$A9
$B0
$B9
$C9
$D9
$E9
$ED
$EE
Type
ACK
ACK
ACK
NACK
NACK
NACK
NACK
NACK
NACK
ACK
NACK
NACK
NACK
NACK
NACK
ACK/NACK
6.6.5. Notes
The Write User Zone command is identical for 88SC and 88RF CryptoRF PICCs when PARAM = $00. Automatic data
write verification is performed by 88RF PICCs; this function is not supported by 88SC PICCs.
32 AT88SC0808/1616/3216/6416CRF, AT88RF04C
5276C–RFID–3/09