PIC16C5X
PIC16CR57B
TABLE 15-2: EXTERNAL CLOCK TIMING REQUIREMENTS - PIC16CR57B (CON’T)
AC Characteristics
Standard Operating Conditions (unless otherwise specified)
Operating Temperature
0°C ≤ TA ≤ +70°C (commercial)
–40°C ≤ TA ≤ +85°C (industrial)
–40°C ≤ TA ≤ +125°C (extended)
Operating Voltage VDD range is described in Section 15.1, Section 15.2 and Section 15.3.
Parameter
No.
Sym
Characteristic
Min Typ(1) Max Units
Conditions
1
TOSC External CLKIN Period(2)
250 —
— ns XT osc mode
250 —
— ns HS osc mode (04)
100 —
— ns HS osc mode (10)
50 —
— ns HS osc mode (20)
Oscillator Period(2)
5.0 —
250 —
— µs LP osc mode
— ns RC osc mode
250 — 10,000 ns XT osc mode
250 — 250 ns HS osc mode (04)
100 — 250 ns HS osc mode (10)
50 — 250 ns HS osc mode (20)
2
TCY
Instruction Cycle Time(3)
5.0 — 200
— 4/FOSC —
µs LP osc mode
—
3
TosL, TosH Clock in (OSC1) Low or High Time 85* —
— ns XT oscillator
20* —
— ns HS oscillator
2.0* —
— µs LP oscillator
4
TosR, TosF Clock in (OSC1) Rise or Fall Time
—
—
25* ns XT oscillator
—
—
25* ns HS oscillator
—
—
50* ns LP oscillator
* These parameters are characterized but not tested.
Note 1: Data in the Typical (“Typ”) column is at 5.0V, 25°C unless otherwise stated. These parameters are for design guidance only
and are not tested.
2: All specified values are based on characterization data for that particular oscillator type under standard operating
conditions with the device executing code. Exceeding these specified limits may result in an unstable oscillator operation
and/or higher than expected current consumption.
When an external clock input is used, the “max” cycle time limit is “DC” (no clock) for all devices.
3: Instruction cycle period (TCY) equals four times the input oscillator time base period.
DS30453B-page 126
Preliminary
© 1998 Microchip Technology Inc.