Data Sheet
Absolute Maximum Ratings
The safety of the device is not guaranteed when it is operated above the “Absolute Maximum Ratings”. The device
should not be operated at these “absolute” limits. Adhere to the “Recommended Operating Conditions” for proper
device function. The information contained in the Electrical Characteristics tables and Typical Performance plots reflect
the operating conditions noted on the tables and plots.
Parameter
Supply Voltage
Input Voltage Range
Reliability Information
Parameter
Junction Temperature
Storage Temperature Range
Lead Temperature (Soldering, 10s)
Package Thermal Resistance
5-Lead SOT23
8-Lead MSOP
8-Lead SOIC
14-Lead SOIC
14-Lead TSSOP
Notes:
Package thermal resistance (θJA), JDEC standard, multi-layer test boards, still air.
ESD Protection
Product
Human Body Model (HBM)
Charged Device Model (CDM)
Min
0
-Vs -0.5V
Max
+14
+Vs +0.5V
Min
Typ
Max
150
-65
170
260
221
139
100
88
96
SOIC-8
1k
2k
Unit
V
V
Unit
°C
°C
°C
°C/W
°C/W
°C/W
°C/W
°C/W
Recommended Operating Conditions
Parameter
Operating Temperature Range
Supply Voltage Range
Min
Typ
Max
Unit
-40
+125
°C
2.7
12.6
V
©2013 Exar Corporation
4/23
Rev 1A