ADE3800
Register Description by Block
Table 17: SMEAS Register Definitions (Sheet 6 of 6)
Register Name
Addr Mode Bits Rst
Description
SMEAS_STATUS_RANGE 0152 R
R
R
R
R
R
R
R
SMEAS_MEAS_POLLING 0153 R
R
SMEAS_STATUS_RANGE2 0155 R
R
[7]
00 The meas_sticky_status bit is an OR of the STATUS_MASK
bits ANDed with their corresponding non-sticky range status
flags. This bit is sticky and can only be cleared by a write to
SMEAS_CLEAR[1]. The sticky bit goes to the scaler as a
signal to blank the output screen.
[6]
Indicates that the hpol measurement does not currently equal
the reference value. Not sticky.
[5]
Indicates that the vpol measurement does not currently equal
the reference value. Not sticky.
[4]
Indicates that the fastmute measurement is currently
exceeding the ref+tol. Not sticky.
[3]
Indicates that the xclks per vhi measurement is currently
exceeding the ref+tol. Not sticky.
[2]
Indicates that the horizontal per vertical measurement is
currently exceeding the ref+tol. Not sticky.
[1]
Indicates that the xclks per horizontal measurement is
currently exceeding the ref+tol. Not sticky.
[0]
Indicates that the xclks per vertical measurement is currently
exceeding the ref+tol. Not sticky.
[1]
00 Horizontal measurement polling bit.
Toggles upon completion of each measurement in free-run
mode while SMEAS_H_CTRL[1] = 1. Undefined in one-shot
mode.
[0]
Vertical measurement polling bit.
Toggles upon completion of each measurement in free-run
mode while SMEAS_V_CTRL[1] = 1. Undefined in one-shot
mode.
[1]
indicates the current state of the line buffer pointer crossing
error check in the scaler.
[0]
indicates the current state of the output sequencer trigger-
out-of-range error check
a. The Mask can apply in any mode of operation, it does not need to only apply to the Sticky bit setting.
b. Adjust VSYNC delay and/or filtering in the SRT block to achieve an hv_skew >= 6 to prevent vsync jitter
sensitivity in the SMUX and SMEAS blocks.
4.8 Sync Multiplexer (SMUX)
The SMUX block provides the ability to:
Clamp (ADC Black level capture) pulse generation.
Generate Data Enable from incoming HSync/Vsync signals.
Select which sync source is used as internal reference.
Vertical enable (venab) and clamp are always generated.