OPERATING CONDITIONS (Cont’d)
12.3.2 Operating Conditions with Low Voltage Detector (LVD)
Subject to general operating conditions for VDD, fOSC, and TA.
Symbol
VIT+(LVD)
VIT-(LVD)
Vhys(LVD)
Parameter
Reset release threshold
(VDD rise)
Reset generation threshold
(VDD fall)
LVD voltage threshold hysteresis
Conditions
VIT+(LVD)-VIT-(LVD)
VtPOR
VDD rise time rate 1)
tg(VDD)
Width of filtered glitches on VDD 1)
(which are not detected by the LVD)
Notes:
1. Data based on characterization results, not tested in production.
12.3.3 Auxiliary Voltage Detector (AVD) Thresholds
Subject to general operating condition for VDD, fOSC, and TA.
Symbol
VIT+(AVD)
VIT-(AVD)
Vhyst(AVD)
ΔVIT-
Parameter
1⇒0 AVDF flag toggle threshold
(VDD rise)
0⇒1 AVDF flag toggle threshold
(VDD fall)
AVD voltage threshold hysteresis1)
Voltage drop between AVD flag set
and LVD reset activated)
Conditions
VIT+(AVD)-VIT-(AVD)
VIT-(AVD)-VIT-(LVD)
Notes:
1. Data based on characterization results, not tested in production.
2. See “MAXIMUM VALUES OF AVD THRESHOLDS” on page 304..
ST7MC1xx/ST7MC2xx
Min Typ Max Unit
3.90 4.20 4.50
V
3.80 4.00 4.35
200
mV
20
μs/V
100 ms/V
40
ns
Min Typ Max2) Unit
4.35 4.70 4.90
V
4.20 4.50 4.70
200
mV
450
mV
251/309