3.1.6 SLAVE ADDRESS
After generating a Start condition, the bus master
transmits the slave address consisting of a 7-bit device
code ‘1010000’ for the 24LCS21.
The eighth bit of the slave address determines whether
the master device wants to read or write to the
24LCS21 (Figure 3-5).
The 24LCS21 monitors the bus for its corresponding
slave address continuously. It generates an
Acknowledge bit if the slave address was true and it is
not in a programming mode.
Operation
Slave Address
R/W
Read
1010000
1
Write
1010000
0
24LCS21
FIGURE 3-5:
Start
CONTROL BYTE
ALLOCATION
Read/Write
Slave Address
R/W A
1
0
10
0
0
0
© 2005 Microchip Technology Inc.