ST6208C/ST6209C/ST6210C/ST6220C
A/D CONVERTER (Cont’d)
9.3.5 Low power modes
Mode
WAIT
STOP
Description
No effect on A/D Converter. ADC interrupts
cause the device to exit from Wait mode.
A/D Converter disabled.
Note: The A/D converter may be disabled by clear-
ing the PDS bit. This feature allows reduced power
consumption when no conversion is needed.
9.3.6 Interrupts
Interrupt Event
Event
Flag
Enable
Bit
End of Conver-
sion
EOC
EAI
Exit
from
Wait
Yes
Exit
from
Stop
No
Note: The EOC bit is cleared only when a new
conversion is started (it cannot be cleared by writ-
ing 0). To avoid generating further EOC interrupt,
the EAI bit has to be cleared within the ADC inter-
rupt subroutine.
9.3.7 Register description
A/D CONVERTER CONTROL REGISTER (AD-
CR)
Address: 0D0h - Read/Write (Bit 6 Read Only, Bit
5 Write Only)
Reset value: 01000 0000 (40h)
7
0
EAI EOC STA PDS
D3
OSC
OF F
D1
D0
Bit 7 = EAI Enable A/D Interrupt.
0: ADC interrupt disabled
1: ADC interrupt enabled
Bit 6 = EOC End of conversion. Read Only
When a conversion has been completed, this bit is
set by hardware and an interrupt request is gener-
ated if the EAI bit is set. The EOC bit is automati-
Table 16. ADC Register Map and Reset Values
cally cleared when the STA bit is set. Data in the
data conversion register are valid only when this
bit is set to “1”.
0: Conversion is not complete
1: Conversion can be read from the DR register
Bit 5 = STA: Start of Conversion. Write Only.
0: No effect
1: Start conversion
Note: Setting this bit automatically clears the EOC
bit. If the bit is set again when a conversion is in
progress, the present conversion is stopped and a
new one will take place. This bit is write only, any
attempt to read it will show a logical zero.
Bit 4 = PDS Power Down Selection.
0: A/D converter is switched off
1: A/D converter is switched on
Bit 3 = D3 Not used, must be kept cleared.
Bit 2 = OSCOFF Main Oscillator off.
0: Main Oscillator enabled
1: Main Oscillator disabled
Note: This bit does not apply to the ADC peripher-
al but to the main clock system. Refer to the Clock
System section.
Bit 1:0 = D[1:0] Not used, must be kept cleared.
A/D CONVERTER DATA REGISTER (ADR)
Address: 0D1h - Read only
Reset value: xxh
7
0
D7 D6 D5 D4 D3 D2 D1 D0
Bit 7:0 = D[7:0]: 8 Bit A/D Conversion Result.
Address
(Hex.)
Register
Label
7
6
5
4
3
2
1
0
0D0h
ADR
Reset Value
D7
0
D6
0
D5
0
D4
0
D3
0
D2
0
D1
0
D0
0
0D1h
ADCR
Reset Value
EAI
0
EOC
STA
1
0
PDS
0
D3
0
D2
0
D1
0
D0
0
55/105