DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

TOP257MN 查看數據表(PDF) - Power Integrations, Inc

零件编号
产品描述 (功能)
生产厂家
TOP257MN
Power-Integrations
Power Integrations, Inc 
TOP257MN Datasheet PDF : 50 Pages
First Prev 21 22 23 24 25 26 27 28 29 30 Next Last
TOP252-262
Key Application Considerations
TOPSwitch-HX vs. TOPSwitch-GX
Table 4 compares the features and performance differences
between TOPSwitch-HX and TOPSwitch-GX. Many of the new
features eliminate the need for additional discrete components.
Other features increase the robustness of design, allowing cost
savings in the transformer and other power components.
TOPSwitch-HX vs. TOPSwitch-GX
Function
TOPSwitch-GX
TOPSwitch-HX
TOPSwitch-HX Advantages
EcoSmart
Linear frequency reduction to
30 kHz (@ 132 kHz) for
duty cycles < 10%
Multi-mode operation with
linear frequency reduction to
30 kHz (@ 132 kHz) and
multi-cycle modulation
(virtually no audible noise)
Improved efficiency over load (e.g. at 25% load
point)
Improved standby efficiency
Improved no-load consumption
Output Overvoltage
Protection (OVP)
Not available
Line Feed-Forward with Duty Linear reduction
Cycle Reduction
Switching Frequency DIP-8 132 kHz
Package
User programmable primary Protects power supply output during open loop fault
or secondary hysteretic or Maximum design flexibility
latching OVP
Dual slope reduction with
lower, more accurate onset
point
Improved line ripple rejection
Smaller DC bus capacitor
66 kHz
Increased output power for given MOSFET size due
to higher efficiency
Lowest MOSFET On
3.0 W (TOP246P)
Resistance in DIP-8 Package
I2f Trimming
Not available
Auto-restart Duty Cycle
5.6%
Frequency Jitter
±4 kHz @ 132 kHz
±2 kHz @ 66 kHz
1.8 W (TOP258P)
-10% / +20%
2%
±5 kHz @ 132 kHz
±2.5 kHz @ 66 kHz
Increased output power in designs without external
heat sink
Increased output power for given core size
Reduced over-load power
Reduced delivered average output power during
open loop faults
Reduced EMI filter cost
Thermal Shutdown
External Current Limit
130 °C to 150 °C
30%-100% of ILIMIT
135 °C to 150 °C
Increased design margin
30%-100% of ILIMIT, additional Reduced tolerances when current limit is set
trim at 0.7 × ILIMIT
externally
Line UV Detection Threshold 50 mA (2 MW sense
impedance)
25 mA (4 MW sense
impedance)
Reduced dissipation for lower no-load consumption
Soft-Start
10 ms duty cycle and current 17 ms sweep through
limit ramp
multi-mode characteristic
Table 4. Comparison Between TOPSwitch-GX and TOPSwitch-HX.
Reduced peak current and voltage component
stress at startup
Smooth output voltage rise
www.powerint.com
25
Rev. H 06/13

Share Link: 