DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

FDC37B78X 查看數據表(PDF) - SMSC -> Microchip

零件编号
产品描述 (功能)
生产厂家
FDC37B78X Datasheet PDF : 258 Pages
First Prev 101 102 103 104 105 106 107 108 109 110 Next Last
PARALLEL PORT FLOPPY DISK CONTROLLER
The Floppy Disk Control signals are available
optionally on the parallel port pins. When this
mode is selected, the parallel port is not
available. There are two modes of operation,
PPFD1 and PPFD2. These modes can be
selected in the Parallel Port Mode Register, as
defined in the Parallel Port Mode Register,
Logical Device 3, at 0xF1. PPFD1 has only
drive 1 on the parallel port pins; PPFD2 has
drive 0 and 1 on the parallel port pins.
When the PPFDC is selected the following pins
are set as follows:
1. nPDACK: high-Z
2. PDRQ: not ECP = high-Z, ECP & dmaEn =
0, ECP & not dmaEn = high-Z
3. PINTR: not active, this is hi-Z or Low
depending on settings.
Note: nPDACK, PDRQ and PINTR refer to the
nDACK, DRQ and IRQ chosen for the parallel
port.
The following parallel port pins are read as
follows by a read of the parallel port register:
1. Data Register (read) = last Data Register
(write)
1. Control Register read as "cable not
connected" STROBE, AUTOFD and SLC =
0 and nINIT =1
3. Status Register reads: nBUSY = 0, PE = 0,
SLCT = 0, nACK = 1, nERR = 1
The following FDC pins are all in the high
impedence state when the PPFDC is actually
selected by the drive select register:
1. nWDATA, DENSEL, nHDSEL, nWGATE,
nDIR, nSTEP, nDS1, nDS0, nMTR0,
nMTR1.
2. If PPFDx is selected, then the parallel port
can not be used as a parallel port until
"Normal" mode is selected.
The FDC signals are muxed onto the Parallel
Port pins as shown in TABLE 47.
For ACPI compliance the FDD pins that are
multiplexed onto the Parallel Port function
independently of the state of the Parallel Port
controller. For example, if the FDC is enabled
onto the Parallel Port the multiplexed FDD
interface functions normally regardless of the
Parallel Port Power control, CR22.3. TABLE 46
illustrates this functionality.
TABLE 46 - PARALLEL PORT FDD CONTROL
PARALLEL
PARALLEL PORT FDC
PARALLEL PORT PARALLEL PORT
PORT POWER
CONTROL
FDC STATE
STATE
CR22.3
LD3:CRF1.1 LD3:CRF1.0
1
0
0
OFF
ON
0
0
0
OFF
OFF
X
1
X
ON
OFF
X
1
(NOTE1)
NOTE1: The Parallel Port Control register reads as “Cable Not Connected” when the Parallel Port
FDC is enabled; i.e., STROBE = AUTOFD = SLC = 0 and nINIT = 1.
109

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]