DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

FDC37B78X 查看數據表(PDF) - SMSC -> Microchip

零件编号
产品描述 (功能)
生产厂家
FDC37B78X Datasheet PDF : 258 Pages
First Prev 51 52 53 54 55 56 57 58 59 60 Next Last
TABLE 27 - RESULT PHASE TABLE
FINAL SECTOR
MT
HEAD
TRANSFERRED TO
ID INFORMATION AT RESULT PHASE
HOST
C
H
R
N
0
0
Less than EOT
NC
NC
R+1
NC
Equal to EOT
C+1
NC
01
NC
1
Less than EOT
NC
NC
R+1
NC
Equal to EOT
C+1
NC
01
NC
1
0
Less than EOT
NC
NC
R+1
NC
Equal to EOT
NC
LSB
01
NC
1
Less than EOT
NC
NC
R+1
NC
Equal to EOT
C+1
LSB
01
NC
NC: No Change, the same value as the one at the beginning of command execution.
LSB: Least Significant Bit, the LSB of H is complemented.
Write Data
After the Write Data command has been issued,
the FDC loads the head (if it is in the unloaded
state), waits the specified head load time if
unloaded (defined in the Specify command),
and begins reading ID fields. When the sector
address read from the diskette matches the
sector address specified in the command, the
FDC reads the data from the host via the FIFO
and writes it to the sector's data field.
After writing data into the current sector, the
FDC computes the CRC value and writes it into
the CRC field at the end of the sector transfer.
The Sector Number stored in "R" is incremented
by one, and the FDC continues writing to the
next data field. The FDC continues this "Multi-
Sector Write Operation". Upon receipt of a
terminal count signal or if a FIFO over/under run
occurs while a data field is being written, then
the remainder of the data field is filled with
zeros. The FDC reads the ID field of each
sector and checks the CRC bytes. If it detects a
CRC error in one of the ID fields, it sets the IC
code in Status Register 0 to "01" (abnormal
termination), sets the DE bit of Status Register 1
to "1", and terminates the Write Data command.
The Write Data command operates in much the
same manner as the Read Data command. The
following items are the same. Please refer to the
Read Data Command for details:
Transfer Capacity
EN (End of Cylinder) bit
ND (No Data) bit
Head Load, Unload Time Interval
ID information when the host terminates the
command
Definition of DTL when N = 0 and when N
does not = 0
Write Deleted Data
This command is almost the same as the Write
Data command except that a Deleted Data
Address Mark is written at the beginning of the
Data Field instead of the normal Data Address
Mark. This command is typically used to mark
a bad sector containing an error on the floppy
disk.
Verify
The Verify command is used to verify the data
stored on a disk. This command acts exactly
like a Read Data command except that no data
is transferred to the host. Data is read from the
disk and CRC is computed and checked against
the previously-stored value.
60

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]