32.3 Current consumption
Table 32-4. Current consumption for active mode and sleep modes.
Symbol Parameter
Condition
Active power
consumption (1)
32kHz, ext. clk.
1MHz, ext. clk.
2MHz, ext. clk.
VCC = 1.8V
VCC = 3.0V
VCC = 1.8V
VCC = 3.0V
VCC = 1.8V
32MHz, ext. clk.
VCC = 3.0V
Idle power
consumption (1)
32kHz, ext. clk.
1MHz, ext. clk.
2MHz, ext. clk.
VCC = 1.8V
VCC = 3.0V
VCC = 1.8V
VCC = 3.0V
VCC = 1.8V
ICC
Power-down power
consumption
32MHz, ext. clk.
T = 25°C
T = 85°C
WDT and Sampled BOD enabled,
T = 25°C
WDT and Sampled BOD enabled,
T = 85°C
VCC = 3.0V
VCC = 3.0V
VCC = 3.0V
RTC from ULP clock, WDT and
sampled BOD enabled, T = 25°C
Power-save power
consumption (2)
RTC from 1.024kHz low power
32.768kHz TOSC, T = 25°C
RTC from low power 32.768kHz
TOSC, T = 25°C
Reset power consumption
Current through RESET pin
substracted
VCC = 1.8V
VCC = 3.0V
VCC = 1.8V
VCC = 3.0V
VCC = 1.8V
VCC = 3.0V
VCC = 3.0V
Notes: 1. All Power Reduction Registers set.
2. Maximum limits are based on characterization, and not tested in production.
XMEGA D4
Min.
Typ.
68
145
260
540
460
0.96
9.8
2.4
3.9
62
118
125
240
3.8
0.1
1.2
1.3
Max. Units
µA
600
1.4
mA
12
µA
225
350
5.5
mA
1.0
4.5
3.0
2.4
6.0
1.2
1.3
µA
0.6
2
0.7
2
0.8
3
1.0
3
320
66
8135L–AVR–06/12