DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

C8051F317 查看數據表(PDF) - Silicon Laboratories

零件编号
产品描述 (功能)
生产厂家
C8051F317
Silabs
Silicon Laboratories 
C8051F317 Datasheet PDF : 224 Pages
First Prev 151 152 153 154 155 156 157 158 159 160 Next Last
C8051F310/1/2/3/4/5/6/7
Bit
MASTER
TXMODE
STA
STO
ACKRQ
ARBLOST
ACK
SI
Table 14.3. Sources for Hardware Changes to SMB0CN
Set by Hardware When...
Cleared by Hardware When...
A START is generated.
A STOP is generated.
Arbitration is lost.
START is generated.
A START is detected.
SMB0DAT is written before the start of an
Arbitration is lost.
SMBus frame.
SMB0DAT is not written before the
start of an SMBus frame.
A START followed by an address byte is
Must be cleared by software.
received.
A STOP is detected while addressed as a A pending STOP is generated.
slave.
Arbitration is lost due to a detected STOP.
A byte has been received and an ACK
After each ACK cycle.
response value is needed.
A repeated START is detected as a MASTER Each time SI is cleared.
when STA is low (unwanted repeated START).
SCL is sensed low while attempting to gener-
ate a STOP or repeated START condition.
SDA is sensed low while transmitting a ‘1’
(excluding ACK bits).
The incoming ACK value is low (ACKNOWL- The incoming ACK value is high (NOT
EDGE).
ACKNOWLEDGE).
A START has been generated.
Must be cleared by software.
Lost arbitration.
A byte has been transmitted and an
ACK/NACK received.
A byte has been received.
A START or repeated START followed by a
slave address + R/W has been received.
A STOP has been received.
Rev. 1.6
151