CS1630/31
6.30 Configuration 48 (Config48) Address 80
7
6
5
4
3
2
1
0
OCP_BLANK3 OCP_BLANK2 OCP_BLANK1 OCP_BLANK0 OLP_BLANK2 OLP_BLANK1 OLP_BLANK0 IOTP_SAMP
Number
[ 7:4]
[3:1]
[0]
Name
Description
OCP_BLANK[3:0]
Configures fixed time-blanking interval tOCP for overcurrent protection
(OCP). The value is an unsigned integer in the range of 0value15.
tOCP = 150ns + OCP_BLANK [3:0] 50ns
OLP_BLANK[2:0]
Configures fixed time blanking interval tOLP for open loop protection (OLP)
and sense resistor protection. The value is an unsigned integer in the range
of 0value7.
tOLP = 1s + OLP_BLANK [2:0] 0.5s
IOTP_SAMP
Sample internal temperature sensor at a slower rate when not in internal
overtemperature state (iOTP fault state). Recommended to set bit
IOTP_SAMP to sample slow.
0 = Sample fast
1 = Sample slow
6.31 Configuration 49 (Config49) Address 81
7
6
5
OCP_CNT2 OCP_CNT1 OCP_CNT0
4
OCP_LAT
3
OLP_CNT2
2
OLP_CNT1
1
OLP_CNT0
0
OLP_LAT
Number
[ 7:5 ]
[4]
[3:1]
[0]
Name
OCP_CNT[2:0]
OCP_LAT
OLP_CNT[2:0]
OLP_LAT
Description
Sets the second stage OCP fault counter threshold used when declaring a
fault.
0 = Force OCP fault (debug only)
1-7= Number of times an OCP fault has to occur consecutively.
Configures OCP fault type.
0 = Unlatched fault
1 = Latched fault
Sets the second stage OLP fault counter threshold used when declaring a
fault.
0 = Force OLP fault (debug only)
1-7= Number of times an OLP fault has to occur consecutively before the
IC will enter a fault state.
Configures OLP fault type.
0 = Unlatched fault
1 = Latched fault
42
DS954F2

Share Link: 