256-Mbit J3 (x8/x16)
Table 25. Query Structure
Offset
Sub-Section Name
Description
00h
Manufacturer Code
01h
Device Code
(BA+2)h(2) Block Status Register
Block-Specific Information
04-0Fh Reserved
Reserved for Vendor-Specific Information
10h
CFI Query Identification String
Reserved for Vendor-Specific Information
1Bh
System Interface Information
Command Set ID and Vendor Data Offset
27h
Device Geometry Definition
Flash Device Layout
P(3)
Primary Intel-Specific Extended
Query Table
Vendor-Defined Additional Information
Specific to the Primary Vendor Algorithm
NOTES:
1. Refer to the Query Structure Output section and offset 28h for the detailed definition of offset
address as a function of device bus width and mode.
2. BA = Block Address beginning location (i.e., 02000h is block 2’s beginning location when the
block size is 128 Kbyte).
3. Offset 15 defines “P” which points to the Primary Intel-Specific Extended Query Table.
Notes
1
1
1,2
1
1
1
1
1,3
A.3
Block Status Register
The block status register indicates whether an erase operation completed successfully or whether a
given block is locked or can be accessed for flash program/erase operations.
Table 26. Block Status Register
Offset Length
Description
Address
Value
(BA+2)h(1)
1 Block Lock Status Register
BA+2: --00 or --01
BSR.0 Block Lock Status
0 = Unlocked
1 = Locked
BA+2: (bit 0): 0 or 1
BSR 1–7: Reserved for Future Use
BA+2: (bit 1–7): 0
NOTE:
1. BA = The beginning location of a Block Address (i.e., 008000h is block 1’s (64-KB block) beginning location
in word mode).
A.4
CFI Query Identification String
The CFI Query Identification String provides verification that the component supports the
Common Flash Interface specification. It also indicates the specification version and supported
vendor-specified command set(s).
Table 27. CFI Identification (Sheet 1 of 2)
Offset Length
Description
10h
3 Query-unique ASCII string “QRY”
13h
2 Primary vendor command set and control interface ID code.
16-bit ID code for vendor-specified algorithms
15h
2 Extended Query Table primary algorithm address
17h
2 Alternate vendor command set and control interface ID code.
Add.
10
11:
12:
13:
14:
15:
16:
17:
Hex
Code
--51
--52
--59
--01
--00
--31
--00
--00
Value
“Q”
“R”
“Y”
54
Datasheet