DC and AC parameters
M29W320DT, M29W320DB
Table 11. DC Characteristics
Symbol
Parameter
ILI Input Leakage Current
ILO Output Leakage Current
ICC1 Supply Current (Read)
ICC2 Supply Current (Standby)
ICC3(1)
Supply Current
(Program/Erase)
VIL Input Low Voltage
VIH Input High Voltage
VPP
Voltage for VPP/WP
Program Acceleration
IPP
Current for VPP/WP
Program Acceleration
VOL
VOH
VID
IID
VLKO
Output Low Voltage
Output High Voltage
Identification Voltage
Identification Current
Program/Erase Lockout
Supply Voltage
1. Sampled only, not 100% tested.
Test Condition
0V ≤VIN ≤VCC
0V ≤VOUT ≤VCC
E = VIL, G = VIH,
f = 6MHz
E = VCC ±0.2V,
RP = VCC ±0.2V
Program/Eras
e
Controller
active
VPP/WP =
VIL or VIH
VPP/WP =
VPP
VCC = 3.0V ±10%
VCC = 3.0V ±10%
IOL = 1.8mA
IOH = –100µA
A9 = VID
Min
–0.5
0.7VCC
11.5
VCC –0.4
11.5
1.8
Typ.
5
35
Max Unit
±1
µA
±1
µA
10
mA
100
µA
20
mA
20
mA
0.8
V
VCC +0.3 V
12.5
V
10
mA
0.45
V
V
12.5
V
100
µA
2.3
V
32/56