13.0
Specifications
PSD5XX Family
13.1 Absolute Maximum Ratings
Symbol
Parameter
Condition
TSTG
Storage Temperature
CLDCC
PLDCC
Commercial
Operating Temperature Industrial
Military
Voltage on any Pin
With Respect to GND
VPP
Programming
Supply Voltage
With Respect to GND
Min
– 65
– 65
0
– 40
– 55
– 0.6
– 0.6
Max Unit
+ 150 °C
+ 125 °C
+ 70
°C
+ 85
°C
+ 125 °C
+7
V
+ 14
V
VCC
Supply Voltage
ESD Protection
With Respect to GND – 0.6
+7
V
>2000
V
NOTE:
Stresses above those listed under Absolute Maximum Ratings may cause permanent
damage to the device. This is a stress rating only and functional operation of the device at
these or any other conditions above those indicated in the operational sections of this
specification is not implied. Exposure to Absolute Maximum Rating conditions for
extended periods of time may affect device reliability.
13.2 Operating Range
Type
Temperature
Commercial 0° C to +70°C
Industrial
–40° C to +85°C
VC C
VCC Tolerance
Speed Grades Available
-70 -90 -15 -20 -25
+5V
± 10%
X
X
+3V
± 10%
XX
+5V
± 10%
X
+3V
± 10%
X
13.3 Recommended Operating Conditions
Symbol Parameter
Condition
VCC Supply Voltage All Speeds
VCC
Supply Voltage
ZPSD5XXV Versions
Only, All Speeds
Min Typ Max Unit
4.5 5.0 5.5
V
2.7 3.0 5.5
V
109