DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

TS83C51RB2-VCKB 查看數據表(PDF) - Atmel Corporation

零件编号
产品描述 (功能)
生产厂家
TS83C51RB2-VCKB
Atmel
Atmel Corporation 
TS83C51RB2-VCKB Datasheet PDF : 74 Pages
First Prev 61 62 63 64 65 66 67 68 69 70 Next Last
TS80C51RA2/RD2
TS83C51RB2/RC2/RD2
TS87C51RB2/RC2/RD2
10.5. AC Parameters
10.5.1. Explanation of the AC Symbols
Each timing symbol has 5 characters. The first character is always a “T” (stands for time). The other characters,
depending on their positions, stand for the name of a signal or the logical status of that signal. The following is
a list of all the characters and what they stand for.
Example:TAVLL = Time for Address Valid to ALE Low.
TLLPL = Time for ALE Low to PSEN Low.
TA = 0 to +70°C (commercial temperature range); VSS = 0 V; VCC = 5 V ± 10%; -M and -V ranges.
TA = -40°C to +85°C (industrial temperature range); VSS = 0 V; VCC = 5 V ± 10%; -M and -V ranges.
TA = 0 to +70°C (commercial temperature range); VSS = 0 V; 2.7 V < VCC < 5.5 V; -L range.
TA = -40°C to +85°C (industrial temperature range); VSS = 0 V; 2.7 V < VCC < 5.5 V; -L range.
Table 34. gives the maximum applicable load capacitance for Port 0, Port 1, 2 and 3, and ALE and PSEN signals.
Timings will be guaranteed if these capacitances are respected. Higher capacitance values can be used, but timings
will then be degraded.
Port 0
Port 1, 2, 3
ALE / PSEN
Table 34. Load Capacitance versus speed range, in pF
-M
-V
-L
100
50
100
80
50
80
100
30
100
Table 36., Table 39. and Table 42. give the description of each AC symbols.
Table 37., Table 40. and Table 43. give for each range the AC parameter.
Table 38., Table 41. and Table 44. give the frequency derating formula of the AC parameter. To calculate each
AC symbols, take the x value corresponding to the speed grade you need (-M, -V or -L) and replace this value
in the formula. Values of the frequency must be limited to the corresponding speed grade:
Table 35. Max frequency for derating formula regarding the speed grade
Freq (MHz)
T (ns)
-M X1 mode
40
25
-M X2 mode
20
50
-V X1 mode
40
25
-V X2 mode
30
33.3
-L X1 mode
30
33.3
-L X2 mode
20
50
Example:
TLLIV in X2 mode for a -V part at 20 MHz (T = 1/20E6 = 50 ns):
x= 22 (Table 38.)
T= 50ns
TLLIV= 2T - x = 2 x 50 - 22 = 78ns
62
Rev. C - 06 March, 2001

Share Link: 