M29W640DT, M29W640DB
Figure 18. In-System Equipment Group Protect Flowchart
START
n=0
RP = VID
WRITE 60h
ADDRESS = GROUP ADDRESS
A0 = VIL, A1 = VIH, A6 = VIL
WRITE 60h
ADDRESS = GROUP ADDRESS
A0 = VIL, A1 = VIH, A6 = VIL
Wait 100µs
WRITE 40h
ADDRESS = GROUP ADDRESS
A0 = VIL, A1 = VIH, A6 = VIL
Wait 4µs
READ DATA
ADDRESS = GROUP ADDRESS
A0 = VIL, A1 = VIH, A6 = VIL
DATA NO
=
01h
YES
RP = VIH
ISSUE READ/RESET
COMMAND
PASS
++n NO
= 25
YES
RP = VIH
ISSUE READ/RESET
COMMAND
FAIL
Note: 1. Block Protection Groups are shown in APPENDIX D., Table 19. and Table 20..
2. RP can be either at VIH or at VID when using the In-System Technique to protect the Extended Block.
46/49
AI05576