Electrical characteristics
STM8S007C8
9.3
Operating conditions
The device must be used in operating conditions that respect the parameters in Table 16. In
addition, full account must be taken of all physical capacitor characteristics and tolerances.
Table 16. General operating conditions
Symbol
Parameter
Conditions
Min Max Unit
-
fCPU Internal CPU clock frequency
-
0
24
MHz
0
16
VDD/VDD_IO Standard operating voltage
-
VCAP(1)
CEXT: capacitance of external
capacitor
-
ESR of external capacitor
ESL of external capacitor
At 1 MHz(2)
2.95 5.5
V
470 3300 nF
-
0.3 ohm
-
15
nH
PD(3)
Power dissipation at
TA = 85° C for suffix 6
48-pin devices, with output
on eight standard ports, two
high sink ports and two open
-
drain ports simultaneously(4)
443 mW
TA
Ambient temperature for 6
suffix version
Maximum power dissipation
-40
85
°C
TJ
Junction temperature range
-
-40 105
1. Care should be taken when selecting the capacitor, due to its tolerance, as well as the parameter
dependency on temperature, DC bias and frequency in addition to other factors. The parameter
specifications must be respected for the full application range.
2. This frequency of 1 MHz as a condition for VCAP parameters is given by the design of the internal regulator.
3.
To calculate PDmax(TA),
characteristics on page
use the
86) with
formula PDmax = (TJmax -
the value for TJmax given
TA)/JA (see Section 10.2:
in Table 16 above and the
Thermal
value for
JA
given
in
Table 50: Thermal characteristics.
4. Refer to Section 10.2: Thermal characteristics on page 86 for the calculation method.
46/92