TDA75610SLV
Software specifications
Table 12. DB4
Bit
Instruction decoding bit
D7 Thermal warning 2 active (D7 = 1), Tj = 145 °C (Typ) -
D6 Thermal warning 3 active (D6 = 1) Tj = 125 °C (Typ) -
Channel RR (CH4)
Channel RR (CH4)
D5
Current detection IB2 (D7) = 0
Output peak current < 250 mA - Open load (D5 = 1)
Current detection IB2 (D7) = 1
Output peak current < 125 mA - Open load (D5 = 1)
Output peak current > 500 mA - Normal load (D5 = 0) Output peak current > 250 mA - Normal load (D5 = 0)
Channel RR (CH4)
D4 Turn-on diagnostic (D4 = 0)
-
Permanent diagnostic (D4 = 1)
Channel R (CH4)
D3 R Normal load (D3 = 0)
-
Short load (D3 = 1)
Channel RR (CH4)
Turn-on diag.: No open load (D2 = 0)
D2 Open load detection (D2 = 1)
-
Permanent diag.: No output offset (D2 = 0)
Output offset detection (D2 = 1)
Channel RR (CH4)
D1 No short to Vcc (D1 = 0)
-
Short to Vcc (D1 = 1)
Channel RR (CH4)
D0 No short to GND (D1 = 0)
-
Short to GND (D1 = 1)
DocID025599 Rev 6
35/42
41