ST7265x
EMC CHARACTERISTICS (Cont’d)
13.7.2 Electro Magnetic Interference (EMI)
Based on a simple application running on the product (toggling 2 LEDs through the I/O ports), the product
is monitored in terms of emission. This emission test is in line with the norm SAE J 1752/3 which specifies
the board and the loading of each pin.
Symbol
Parameter
SEMI Peak level
Conditions
Monitored
Frequency Band
0.1MHz to 30MHz
VDD=5V, TA=+25°C,
30MHz to 130MHz
TQFP64 package
conforming to SAE J 1752/3 130MHz to 1GHz
SAE EMI Level
Max vs. [fOSC/fCPU]
3MHz 6MHz
21
28
16
30
8
31
2
4
Unit
dBµV
-
Note 1. Data based on characterization results, not tested in production.
13.7.3 Absolute Electrical Sensitivity
Based on three different tests (ESD, LU and DLU)
using specific measurement methods, the product
is stressed in order to determine its performance in
terms of electrical sensitivity. For more details, re-
fer to the AN1181 ST7 application note.
13.7.3.1 Electro-Static Discharge (ESD)
Electro-Static Discharges (3 positive then 3 nega-
tive pulses separated by 1 second) are applied to
the pins of each sample according to each pin
combination. The sample size depends on the
number of supply pins of the device (3 parts*(n+1)
supply pin). One model is simulated: Human Body
Model. This test conforms to the JESD22-A114A
standard. See Figure 80 and the following test se-
quence.
Human Body Model Test Sequence
– CL is loaded through S1 by the HV pulse gener-
ator.
– S1 switches position from generator to R.
– A discharge from CL through R (body resistance)
to the ST7 occurs.
– S2 must be closed 10 to 100ms after the pulse
delivery period to ensure the ST7 is not left in
charge state. S2 must be opened at least 10ms
prior to the delivery of the next pulse.
Absolute Maximum Ratings
Symbol
VESD(HBM)
Ratings
Electro-static discharge voltage
(Human Body Model)
Conditions
TA=+25°C
Maximum value 1) Unit
1500
V
Figure 80. Typical equivalent ESD Circuit
S1
R=1500Ω
HIGH VOLTAGE
PULSE
GENERATOR
CL=100pF
ST7
S2
HUMAN BODY MODEL
Note 1: Data based on characterization results, not tested in production.
138/166