STPS20150C
Symbol
IR(1)
VF(2)
Table 4: Static electrical characteristics (per diode)
Characteristics
Parameter
Test conditions
Min. Typ. Max. Unit
Reverse leakage current
Forward voltage drop
Tj = 25 °C
Tj = 125 °C
Tj = 25 °C
Tj = 125 °C
Tj = 25 °C
Tj = 125 °C
VR = VRRM
IF = 10 A
IF = 20 A
-
5.0 µA
-
5.0 mA
-
0.92
- 0.69 0.75
V
-
1
- 0.79 0.86
Notes:
(1)Pulse test: tp = 5 ms, δ < 2%
(2)Pulse test: tp = 380 µs, δ < 2%
To evaluate the conduction losses use the following equation:
P = 0.64 x IF(AV) + 0.011 IF2(RMS)
DocID7756 Rev 11
3/15