I²C and RF command sets
M24SR02-Y
5.6
5.6.1
NFC Forum Type 4 Tag protocol
Commands set
With the NFC Forum Type 4 Tag protocol, the commands are common to RF and I²C.
Table 23. Command set overview
Command name
Brief description
NDEF Tag Application Select
Capability Container Select
NDEF Select
System File Select
Select the NDEF Tag Application
Select the capability container (CC) file using the
Select command
Select the NDEF file
Select the system file
ReadBinary
UpdateBinary
Read data from a file
Write new data to a file
5.6.2
Status and error codes
This section lists the status and the error code of the M24SR02-Y.
Value
Table 24. Status code of the M24SR02-Y
SW1
SW2
Comment
0x90
0x00
Command completed
successfully
Length
Value
Value
Value
Value
Value
Value
Value
Value
Value
Table 25. Error code of the M24SR02-Y
SW1
SW2
Comment
1 byte
1 byte
0x62
0x62
0x63
0x63
0x65
0x67
0x69
0x69
0x69
0x80
0x82
0x00
0xCX
0x81
0x00
0x81
0x82
0x84
File overflow (Le error)
End of file or record reached
before reading Le bytes
Password is required
Password is incorrect, X further
retries allowed (X can take
value 0,1, 2)
Unsuccessful updating
Wrong length
Cmd is incompatible with the
file structure
Security status not satisfied
Reference data not usable
36/90
DocID025386 Rev 10