I²C and RF command sets
M24SR02-Y
Table 31 defines the R-APDU of the NDEF Select command.
Length
Value
Value
Table 31. R-APDU of the NDEF Select command
Data
SW1
SW2
Comment
-
1 byte
1 byte
-
-
0x90
-
0x6A
0x00
0x82
Command completed
File or application not found
5.6.6
System File Select command
The RF or I²C host uses this command to select the system file.
The System file is selected when this command returns "command completed" in the R-
APDU.
Table 32 defines the C-APDU of the command to select the System file (called System
Select).
Table 32. C-APDU of the System File Select command
Name
CLA
INS
P1
P2
Lc
Data
Le
0x00
0xA4
0x00
0x0C
0x02
0xE101
-
Class byte
Select instruction code
P1 field
P2 field
Number of bytes of data
System file ID
-
Table 33 defines the R-APDU of the System File Select command.
Length
Value
Value
Table 33. R-APDU of the System File Select command
Data
SW1
SW2
Comment
-
1 byte
1 byte -
-
0x90
0x00
Command completed
-
0x6A
0x82
Capability container not found, no data
is returned
40/90