Data Measurement Block
ADE3XXX
Table 16: Data Measurement Registers (Sheet 3 of 5)
Register Name
DMEAS_WIN_DMM_MINY_H
DMEAS_WIN_DMM_MAXY_L
DMEAS_WIN_DMM_MAXY_H
DMEAS_PHM_EDGESEL
DMEAS_DMM_EDGESEL
DMEAS_PHM_MODE_CTRL
Addr
0x0911
0x0912
0x0913
0x0914
0x0915
0x0916
Mode Bits
[7:4]
R/W
[3:0]
R/W
[7:0]
[7:4]
R/W
[3:0]
[7:2]
R/W
[1]
R/W
[0]
[7:2]
R/W
[1]
R/W
[0]
[7:5]
R/W
[4]
R/W
[3]
R/W
[2]
R/W
[1]
R/W
[0]
Default
Description
Reserved
minimum Y DMM window [11:8]
relative to vsync
0xFFF
0xFFF
0x0
0x0
0x0
0x0
0x0
maximum Y DMM window [7:0]
Reserved
maximum Y DMM window [11:8]
relative to vsync
Reserved
vsync edge select for PHM measurements
0: rising edge
1: falling edge
hsync edge select for PHM measurements
0: rising edge
1: falling edge
Reserved
vsync edge select for DMM measurements
0: rising edge
1: falling edge
hsync edge select for DMM measurements
0: rising edge
1: falling edge
Reserved
clear PHM result registers
0x0
0: Do not freeze the results in Free-running
mode. New result will be available on the next
and subsequent toggle of the polling bit.
1: Freeze the current results in Free-running
mode. The polling bit will still toggle and the
block continues to free run; however, results
will not update.
No meaning in one-shot mode.
0x0
PHM measurement polling bit. Toggles at the
end of each measurement in free-run mode.
Undefined in one-shot mode.
0x0
PHM algorithm measurement start.
In free-run mode it enables measurements. In
one-shot mode it triggers the start of a
measurement and is reset to zero when the
measurement is complete.
0x0
0: PHM free-run mode.
1: PHM one-shot mode.
46/88