DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

C8051F38B-GMR View Datasheet(PDF) - Silicon Laboratories

Part Name
Description
Manufacturer
C8051F38B-GMR
Silabs
Silicon Laboratories 
C8051F38B-GMR Datasheet PDF : 321 Pages
First Prev 301 302 303 304 305 306 307 308 309 310 Next Last
C8051F380/1/2/3/4/5/6/7/C
The 8-bit offset held in PCA0CPH4 is compared to the upper byte of the 16-bit PCA counter. This offset
value is the number of PCA0L overflows before a reset. Up to 256 PCA clocks may pass before the first
PCA0L overflow occurs, depending on the value of the PCA0L when the update is performed. The total off-
set is then given (in PCA clocks) by Equation 27.4, where PCA0L is the value of the PCA0L register at the
time of the update.
Offset = 256 PCA0CPL4+ 256 PCA0L
Equation 27.4. Watchdog Timer Offset in PCA Clocks
The WDT reset is generated when PCA0L overflows while there is a match between PCA0CPH4 and
PCA0H. Software may force a WDT reset by writing a 1 to the CCF4 flag (PCA0CN.4) while the WDT is
enabled.
27.4.2. Watchdog Timer Usage
To configure the WDT, perform the following tasks:
1. Disable the WDT by writing a 0 to the WDTE bit.
2. Select the desired PCA clock source (with the CPS2CPS0 bits).
3. Load PCA0CPL4 with the desired WDT update offset value.
4. Configure the PCA Idle mode (set CIDL if the WDT should be suspended while the CPU is in Idle
mode).
5. Enable the WDT by setting the WDTE bit to 1.
6. Reset the WDT timer by writing to PCA0CPH4.
The PCA clock source and Idle mode select cannot be changed while the WDT is enabled. The watchdog
timer is enabled by setting the WDTE or WDLCK bits in the PCA0MD register. When WDLCK is set, the
WDT cannot be disabled until the next system reset. If WDLCK is not set, the WDT is disabled by clearing
the WDTE bit.
The WDT is enabled following any reset. The PCA0 counter clock defaults to the system clock divided by
12, PCA0L defaults to 0x00, and PCA0CPL4 defaults to 0x00. Using Equation 27.4, this results in a WDT
timeout interval of 256 PCA clock cycles, or 3072 system clock cycles. Table 27.3 lists some example tim-
eout intervals for typical system clocks.
Rev. 1.4
309

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]