CLP270M
Fig. 14: CLP270M response to a positive surge.
Fig. 15: CLP270M reponse to a negative surge.
switches on within 250ns and withstands the 500A given by the BELLCORE 2/10µs generator.
3.2.2. Speech mode
Figures 14 and 15 give the voltage and current behavior during positive and negative 2.5kV, 2/10µs, 500A
surge tests using a LCP1511D as second stage protection device. The firing threshold values are now
adjusted to GND and to -Vbat (-48V) by the action of the second stage protection which acts as an external
voltage reference.
12/24