CS1630/31
6.34 Configuration 52 (Config52) – Address 84
7
6
5
4
3
2
1
0
COP_THRES6 COP_THRES5 COP_THRES4 COP_THRES3 COP_THRES2 COP_THRES1 COP_THRES0 COP_INT
Number
[ 7:1 ]
[0]
Name
Description
Value used to determine the COP Filter Threshold. The clamp is sampled
every 20s and over the selected interval is compared to COP time-on
threshold, TON(th) to determine if an COP fault has occurred.
COP_THRES[6:0] For a 1 second interval:
TONth = COP_THRES [6:0] 5.12ms + 2.56ms
For a 2 second interval:
TONth = COP_THRES [6:0] 10.24ms + 5.12ms
COP_INT
Configures the time interval to check for a boost stage COP fault.
0 = 1 second interval
1 = 2 second interval
44