M29W640FT, M29W640FB
7 DC and AC parameters
7 DC and AC parameters
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC Characteristic tables that follow
are derived from tests performed under the Measurement Conditions summarized in the
relevant tables. Designers should check that the operating conditions in their circuit match the
measurement conditions when relying on the quoted parameters.
Table 10. Operating and AC Measurement Conditions
Parameter
M29W640FT, M29W640FB
Unit
Min
Max
VCC Supply Voltage
Ambient Operating Temperature
2.7
3.6
V
–40
85
°C
Load Capacitance (CL)
Input Rise and Fall Times
30
pF
10
ns
Input Pulse Voltages
Input and Output Timing Ref. Voltages
0 to VCC
V
VCC/2
V
Figure 6. AC Measurement I/O Waveform
VCC
0V
Figure 7. AC Measurement Load Circuit
VPP
VCC
VCC/2
AI05557
VCC
DEVICE
UNDER
TEST
0.1µF
0.1µF
25k
25k
CL
CL includes JIG capacitance
AI05558
35/72