Operating modes
M48Z35, M48Z35Y
For more information on Battery Storage Life refer to the Application Note AN1012.
Figure 8. Power down/up mode AC waveforms
VCC
VPFD (max)
VPFD (min)
VSO
tF
tFB
tPD
INPUTS
RECOGNIZED
OUTPUTS
VALID
(PER CONTROL INPUT)
tRB
tDR
DON'T CARE
HIGH-Z
tR
trec
RECOGNIZED
VALID
(PER CONTROL INPUT)
AI01168C
Table 5. Power down/up AC characteristics
Symbol
Parameter(1)
Min
Max
Unit
tPD
E or W at VIH before power down
0
µs
tF(2)
VPFD (max) to VPFD (min) VCC fall time
300
µs
tFB(3)
VPFD (min) to VSS VCC fall time
10
µs
tR
VPFD (min) to VPFD (max) VCC rise time
10
µs
tRB
VSS to VPFD (min) VCC rise time
1
µs
trec
VPFD (max) to inputs recognized
40
200
ms
1. Valid for ambient operating temperature: TA = 0 to 70°C; VCC = 4.75 to 5.5V or 4.5 to 5.5V (except where noted).
2. VPFD (max) to VPFD (min) fall time of less than tF may result in deselection/write protection not occurring until 200µs after
VCC passes VPFD (min).
3. VPFD (min) to VSS fall time of less than tFB may cause corruption of RAM data.
Table 6. Power down/up trip points DC characteristics
Symbol
Parameter(1)
Min
Typ
Max
Unit
VPFD Power-fail deselect voltage
M48Z35
4.5
M48Z35Y
4.2
4.6
4.75
4.35
4.5
VSO Battery back-up switchover voltage M48Z35/Y
3.0
tDR(2) Expected data retention time
10
1. Valid for ambient operating temperature: TA = 0 to 70°C; VCC = 4.75 to 5.5V or 4.5 to 5.5V (except where noted).
2. At 25°C, VCC = 0V.
Note:
All voltages referenced to VSS.
V
V
V
YEARS
12/23