M48Z35, M48Z35Y
4
DC and AC parameters
DC and AC parameters
Note:
This section summarizes the operating and measurement conditions, as well as the DC and
AC characteristics of the device. The parameters in the following DC and AC Characteristic
tables are derived from tests performed under the Measurement Conditions listed in Table 8:
Operating and AC measurement conditions. Designers should check that the operating
conditions in their projects match the measurement conditions when using the quoted
parameters.
Table 8.
Operating and AC measurement conditions
Parameter
M48Z35
M48Z35Y
Unit
Supply voltage (VCC)
Ambient operating temperature (TA)
Load capacitance (CL)
Input rise and fall times
Input pulse voltages
Input and output timing ref. voltages
4.75 to 5.5V
4.5 to 5.5
V
0 to 70
0 to 70
°C
100
100
pF
≤5
≤5
ns
0 to 3
0 to 3
V
1.5
1.5
V
Output Hi-Z is defined as the point where data is no longer driven.
Figure 10. AC measurement load circuit
DEVICE
UNDER
TEST
645Ω
CL = 100pF or
5pF
1.75V
CL includes JIG capacitance
AI03211
Table 9.
Symbol
Capacitance
Parameter(1)(2)
Min
Max
CIN Input capacitance
10
CIO(3) Input / output capacitance
10
1. Effective capacitance measured with power supply at 5V. Sampled only, not 100% tested.
2. Outputs deselected.
3. At 25°C.
Unit
pF
pF
15/23